version: "2026.1.0"
language: "en"
---
# Connect to Mobile Device

The **Connect to Mobile Device** block is used to connect a flow to one of the available mobile configurations. It lets you pick a specific configuration instead of always using the default one applied to all flows, so you can target different devices or environments as needed.

Fully expanded, the **Connect to Mobile Device** block shows the following properties:  
![image-20260115-134855.png](https://docs.leapwork.com/__attachments/a_fdde8ab414d72c711d7e7b8aba8a3b5fb23236ede276a79e20a73d0c826bb4c7/image-20260115-134855.png?cb=ac8b4e1ba58bbf899fcede9f171500e9)

**Note:** The screenshot on this page uses the **Elegance Design** , introduced in **2025.3**. If you are using an earlier version, your layout may look different.

## Quick-start

1. Drag **Connect to Mobile Device** onto the canvas.

2. In **Select device configuration** , choose the mobile configuration you want to use, and optionally adjust **Default timeout** and **Timeout (sec)**.

3. Run the flow when it's ready; the block will connect to the selected mobile device before subsequent steps execute.

## Building block parameters

Parameters  
* **Block header:** Shows the current name of the **Connect to Mobile Device** block. You can rename it by double-clicking the header and typing a new title. The green input connector starts the connection attempt when the flow reaches this block, and the green output connector triggers when the device has been successfully connected.

* **Select device configuration:**Displays a list of mobile configurations that have been set up by an administrator.

  * Choose which configuration the flow should use for this connection.

  * The default value corresponds to the configuration selected under **Use configuration** in the flow settings.

* **Error occurred:** Green output connector that triggers if the **Connect to Mobile Device** block returns an error during execution (for example, if the device cannot be reached within the timeout). Use this connector to branch the flow for error handling, retries, or logging.

* **Default timeout:**Controls how the timeout is determined:

  * When the checkbox is **not selected** , the block uses an explicit timeout of **60 seconds** (or whatever value you set in **Timeout (sec)**).

  * When the checkbox is **selected** , the block uses the **Default timeout** value defined in the flow settings.

* **Timeout (sec)** Specifies the maximum time allowed for connecting to the selected device before the block gives up and triggers **Error occurred** .

  This timeout applies only to this block. Each case also has a separate **global timeout** configured in the **Settings** panel; if the case runs longer than that global timeout, it is automatically cancelled regardless of this block's timeout.

## Resources

|                                        **Topic**                                         |                            **Description**                             |
|------------------------------------------------------------------------------------------|------------------------------------------------------------------------|
| [++Mobile connections++](https://docs.leapwork.com/leapwork-flow/latest/administration/connections.md)            | Overview of what's needed to enable mobile automation                  |
| [++Mobile configuration++](https://docs.leapwork.com/leapwork-flow/latest/administration/mobile-configuration.md) | Steps to configure devices and environments for testing                |
| [++Mobile FAQs++](https://docs.leapwork.com/faq/latest/leapwork-flow-faq/mobile-faq.md)                           | Frequently asked questions about mobile automation and troubleshooting |